Topic - Dell Poweredge R610 Fan speed
Posted: 30 Jan 2022 at 1:55pm By reaper
Howto: Setting the fan speed of the Dell R610/R710
Enable IPMI in iDrac
Install ipmitool on linux, win or mac os
Run the following command to issue IPMI commands: ipmitool -I lanplus -H <iDracip> -U root -P <rootpw> <command>
Enable manual/static fan speed:

raw 0x30 0x30 0x01 0x00

Set fan speed:

(Use i.e http://www.hexadecimaldictionary.com/hexadecimal/0x14/ to calculate speed from decimal to hex)

3000 RPM: raw 0x30 0x30 0x02 0xff 0x10

2160 RPM: raw 0x30 0x30 0x02 0xff 0x0a

1560 RPM: raw 0x30 0x30 0x02 0xff 0x09

Note: The RPM may differ from model to model

Disable / Return to automatic fan control:

raw 0x30 0x30 0x01 0x01

Other: List all output from IPMI

sdr elist all or full

Example of a command:

ipmitool -I lanplus -H 192.168.0.120 -U root -P calvin raw 0x30 0x30 0x02 0xff 0x10

ipmitool -I lanplus -H 192.168.0.120 -U root -P calvin raw 0x30 0x30 0x02 0xff 0x23 for 35% speed